← Back to Solutions
Medium Voltage Solutions

High-efficiency medium voltage systems for horizontal pumping and fluid transfer.

The medium voltage portfolio includes the MAGNETA HPS MV PMM system, MIPS Compact, MIPS Large, and the MAGNETA HPS MV PMM motor. These solutions combine advanced power electronics, permanent magnet technology, intelligent control, and SCADA-ready integration for demanding field operations.

MAGNETA HPS MV PMM Integrated system for multiphase transfer, injection, gas compression, and crude transfer with energy savings above 30%.
MIPS Compact / Large Medium voltage intelligent pumping platforms from 300 HP to 14,600 HP and 2.3 kV to 34.5 kV.
MV PMM Motor High-speed permanent magnet motor platform with 96% efficiency and near-unity power factor.
Medium Voltage Solutions
01 Power Range

Solutions from 300 HP to 14,600 HP to support high-demand HPS, booster, and transfer applications.

02 Voltage Flexibility

Architectures spanning 2.3 kV to 34.5 kV, including compact and large-format medium voltage packages.

03 Energy Performance

Permanent magnet technology, FOS control, and optimized drive operation support energy savings above 30%.

04 Integration Ready

SCADA and DCS connectivity through Ethernet TCP/IP and Modbus-based communication protocols.

Overview

MAGNETA HPS MV PMM system overview

The medium voltage line is centered on the MAGNETA HPS MV PMM system for horizontal pumping and fluid-transfer operations. The system combines a medium voltage drive architecture with the MAGNETA high-efficiency surface MV PMM motor to reduce energy consumption, lower the carbon footprint, and keep torque constant across the usable speed range up to nominal speed.

System Value

Built for high-demand transfer and pumping services

MAGNETA HPS MV PMM is designed for multiphase transfer, water, steam, or gas injection, gas compression, and crude transfer. The package is built around advanced motor-control algorithms, high-efficiency permanent magnet technology, and compact equipment architecture that reduces footprint while improving operating efficiency.

Flux Oriented Sensorless (FOS) control maximizes the PMM advantage, while programmable ramp-up and ramp-down speed control helps adapt the operation to process requirements.

MIPS

MIPS Compact and MIPS Large

The MIPS family is available in two medium voltage intelligent pumping configurations. Both are designed to integrate power electronics, advanced control, and remote operation strategies, while adapting the physical package to field constraints and project scale.

MIPS Compact

Compact medium voltage control architecture

  • Universal intelligent controller for process analysis, control, and optimization.
  • Supports PMM and IM motors in local or remote operation.
  • Designed for compact size, minimal environmental impact, and simplified installation.
  • Supports substation simplification through a compact medium voltage architecture.
MIPS Large

Full medium voltage package for large-scale operations

  • Includes medium voltage switchgear, SDT transformer, MV VFD, auxiliary services, pump control, and controlled environment.
  • Designed for safe and reliable operation in high-demand artificial lift and transfer services.
  • Fully integrable with SCADA and DCS systems through standard communication protocols.
  • Optimized for larger projects that require broader electrical infrastructure in a unified package.
300-14,600 HP Nominal range presented for MIPS Compact and Large HPS / Booster applications.
2.3-34.5 kV Voltage architecture envelope across the medium voltage portfolio.
24-pulse Drive technology used in the MIPS Compact / Large platform.
RJ-45 / Fiber Communication availability for Modbus TCP, Modbus RTU, and EtherNet/IP integration.
Motor Comparison

Why MV PMM architecture stands out

The MAGNETA HPS MV PMM platform is engineered to improve electrical behavior and process efficiency compared with conventional induction-motor configurations in demanding transfer and pumping applications.

Performance gains

Electrical and operational advantages

  • Power factor at or above 0.95, improving reactive power behavior.
  • Up to 20% lower no-load current for the same nominal power class.
  • Approximately 15% lower starting current requirement.
  • Efficiency at or above 96% with constant torque across the speed range.
Applications

Designed for heavy-duty process services

  • Multiphase fluid transfer with improved flow handling.
  • Water, steam, or gas injection under stable process conditions.
  • Gas compression with high-speed permanent magnet performance.
  • Reliable crude transfer for production and storage systems.
Technical Data

MIPS platform specifications

Main Electrical Range

  • Nominal power: 300 / 400 / 600 / 800 / 1100 / 1500 / 2000 / 2500 / 6000 / 10000 / 14600 HP.
  • Power supply voltages: 2.4 / 3.0 / 3.3 / 4.16 / 6.0 / 6.3 / 6.6 / 6.9 / 7.2 / 10.0 / 11.0 / 13.8 kV.
  • Frequency: 60 Hz ± 5%.
  • Nominal current range: 40 A to 680 A.

Protection and Transformer

  • MIPS Compact uses dry-type transformer architecture.
  • MIPS Large uses three-winding transformer architecture.
  • Protection cells include disconnector, fuse, and vacuum contactor combinations depending on package type.
  • Large architecture references 34.5 kV SDT protection with SF6 breaker.

Structure

  • NEMA 3R / IP55 enclosure.
  • Expanded metal IMF 100 structure configuration.
  • Corrosion protection and Zone 3 seismic design reference.
  • Designed for 90% external relative humidity and NSR 10 wind-speed criteria.

Communications

  • RJ-45 port availability.
  • Protocols: Modbus TCP, Modbus RTU, and EtherNet/IP.
  • Available communication layout includes copper and multimode fiber interfaces.
  • Prepared for safe remote operation and supervisory platform integration.
MV PMM Motor

MAGNETA HPS MV PMM motor

The dedicated medium voltage permanent magnet motor platform is available in 300 HP to 2500 HP ratings, including 300 / 350 / 400 / 450 / 600 / 800 / 1500 / 2000 / 2500 HP models, operating at 4160 V and 120 Hz with 3600 RPM nominal speed.

Performance

Efficient high-speed PMM operation

  • Efficiency: 96%.
  • Power factor: 0.95.
  • Four-pole configuration with continuous duty cycle.
  • VFD-based starting method with 10% torque drop reference at 4020 RPM.
Instrumentation

Prepared for monitored industrial service

  • Two RTDs per winding and two RTDs per bearing.
  • Four vibration sensors, two on each DE and NDE bearing.
  • IC666 cooling method and IP55 protection rating.
  • Ambient design reference of 40 °C and altitude up to 1000 m.
3D Preview

Inspect the MV PMM package in 3D

Explore a compact interactive model view of the MAGNETA HPS MV PMM package and open it in a larger modal for closer inspection of its overall geometry and proportions.

>30%Energy savings for the MAGNETA HPS MV PMM system.
-15%Installed power release in a representative MV PMM application case.
+20%Power factor improvement from 0.8 to 0.98 in a documented operating comparison.
-10%kVA reduction in the same MV PMM operating scenario.
Contact

Discuss medium voltage solutions for your operation

Review with BCP Group the scope of MAGNETA HPS MV PMM, MIPS Compact, MIPS Large, and medium voltage PMM motor integration for your field, facility, or transfer project.

Contact Sales